MONITOR HEATING SYSTEM
Section
1:
Description
I
GFSSOO
1-1
SPECIFICATIONS
Model
No.
Type
of
Appliance
Input Rating
Output
Rating
Electrical
Rating
Power
Consumption
Heated
Air
Delivery
'Flue
Pipe Hole
Dimensions
Weight
Inlet
Gas
Supply Pressure
Manifold
Test Pressure
GF3800
Fan
type direct
vent
wall furnace
High
38,OOOBTU/hour(Nat.),
34,500
BTU/hour(LP.)
Low
21.600BTU/hour(Nat.),
21,600
BTU/hour(LP.)
High
30,700BTU/hour(Nat.),
27,900
BTU/hour(LP.)
Low
17,500BTU/hour(Nat.),
17,500
BTU/hour(LP.)
120
V, 60 Hz,
Less
than
2
amperes
80
Watts
High
388
Cubic
feet/minute
Low
300
Cubic feet/minute
2.5
inches diameter
Height:
26.6 inches (67.56cm)
Width:
28.7 inches (72.90cm)
Depth: 14.0 inches (35.50cm)
82
pounds
Nat.
Gas
Max. 10.5 inch W.C. (267
mmHzO)
Min.
5.1
inch W.C. (130
mmHzO)
LP. Gas
Max. 13.0 inch W.C. (330
mmH
2
O)
Min.
11.0
inch W.C. (279
mrnHsO)
Nat.
Gas
LP. Gas
3.4
inch W.C.
3.15
inch W.C.
(86mmH
2
O)
(80mmH
2
O)
The
minimum
and
maximum
inlet
gas
supply pressure
are for the
purpose
of
input
adjustment.
1-2
SPECIAL
FEATURES
AUTOMATIC
IGNITION
MEMORY
BACK
UP: Set
memory
can be
kept
in
case
of
power failure
for up to 30
minutes.
DUAL
BLOWERS:
Separate fans
for
combustion
and
room
air
circulation.
THERMOSTATICALLY
CONTROLLED: Adjusts
to
the
desired room temperature.
BUILT-IN TIMER: Heater
will
automatically
operate
as
programmed
by the
user.
AUTOMATIC
RESET
AFTER
POWER
FAILURE:
Heater
will
automatically
resume
operation
after
power
is
restored.
INDICATOR
LIGHTS: Easy-to-see signals show
when
heater
is in
operation, when timer
is
activated,
and
when
the
burner
is
operating.
CLEAN
OPERATION: Products
of
combustion
are
vented
outside.
CONSUMES
NO
ROOM AIR:
Air for
combustion
is
drawn from
outside.
EASY
INSTALLATION: Includes
all
parts required
for
standard
installation.
CHILD
LOCK:
Prevents accidental operation
and
prevents
small children
from
altering
the
controls.
1-3
SAFETY FEATURES
SAFE
RE-LIGHTING: Heater will
not
restart
until
its
combustion chamber
has
cooled.
ELECTRICAL
PROTECTION: Heater automatically
shuts
off in the
unlikely event
of a
malfunction
in
the
electrical circuitry
or
disruption
of the
power
supply.
NO
EXHAUST
IN
ROOM: Products
of
combustion
are
discharged outdoors.
FLUE
PIPE:
Outside
air is
drawn through
a
pipe-
within-a-pipe
venting system. This process
preheats
combustion
air and
regains heat from
exhaust
gases.
^CAUTION:
ALTERNATE POWER SOURCES
The
Monitor GF3800
may not
operate when
powered
by
sources such
as an
auxiliary
generator,
UPS
(Uninterrupted
Power
Source),
inverters,
etc.
This
unit
may not
operate
on a
GFI
(Ground
Fault
Interrupter) power
circuit.
Check
with your dealer
for
guidance
on
specific
applications.

Table of Contents