MONITOR
HEATING
SYSTEM
Section
5:
Troubleshooting
IGF38001
TEST POINT VOLTAGE
All
readings
take
from
EP
(0V)
\.
Operation
""\Mode
Test
Point
\^^
TP1
TP2
TP3
TP4
TP5
TP6
TP7
TP8
Preparation
27V
±50%
12V
±30%
5V
±10%
O.Wmax.
pulse
pulse
at
plug
in
O.Wmax.
1.5
3.2V
Pre-purge
27V
±50%
12V
±30%
5V±10%
O.Wmax.
pulse
5V±10%
O.Wmax.
1.5
3.2V
Igniting
27V
±50%
12V
±30%
5V±10%
infinity variable
pulse
5V±10%
NAT
0.41
-0.84
LP
0.35—0.78
1.5-3.2V
Pre-combustion
27V
±50%
12V
±30%
5V
±10%
1.2Vmin.
pulse
5V±10%
NAT
0.41
-0.84
LP
0.35-0.78
1.5-3.2V
""\^
Operation
\^Mode
Test
Point
^\^
TP1
TP2
TP3
TP4
TP5
TP6
TP7
TP8
High
27V
±50%
12V
±30%
5V
±10%
1
.2Vmin.
pulse
5V±10%
NAT
0.65
-1.05
LP
0.57-0.97
1.5-3.2V
Low
27V
±50%
12V±30%
5V±10%
1.2Vmin.
pulse
5V
±10%
NAT
0.38-0.78
LP
0.32—0.72
1.5-3.2V
Off
27V
±50%
12V
±30%
5V±10%
O.Wmax.
pulse
5V
±10%
O.Wmax.
1.5-3.2V
Post-purge
27V
±50%
12V
±30%
5V
±10%
O.Wmax.
pulse
5V±10%
O.Wmax.
1.5-3.2V
Abnormal
readings
of TP1 and TP2 can be
caused
by
either
failure
of a
transformer
or
PCB.
Abnormal
readings
of
TP3-TP8 caused
by
failure
of
PCB.