SECTION SEVEN – TROUBLESHOOTING
DS2000 USER’S MANUAL (rev.C)
7.4
7.7 RECOVERY RESISTOR TROUBLES
Condition RR Protection Fault (hot resistor).
Check/Correct
- Check recovery resistor wiring
- Check the correct sizing of the recovery resistor. If undersized, replace
with a resistor with same resistance and higher power.
WARNING: Power-off the drive before checking the recovery resistor temperature
Condition RR Protection Fault (cold resistor).
Check/Correct
- Check “Recovery Resist. Resrec”, “Recovery Resist. Power” and
“Recovery Resist. Coeff.” parameters.
WARNING: Power-off the drive before checking the recovery resistor temperature