SECTION FIVE – COMPONENT DESCRIPTION
DS2000 USER’S MANUAL (rev.C)
5.2
5.2 HIGH POWER INPUT SECTION
The high power supply section has the following features:
Three Phase AC Operation
Direct Off-Line 230 V
rms
to 460V
rms
±10% Operation
Soft-start (AC Inrush Current Limiting)
Input Varistor Transient Protection
Drive Ready Relay (DROK)
Provision for External Recovery Resistor
Integral Heat Sink and Cooling Fans
Input 24V Logic Backup
Internal inductance only for size E
These features are described in the next sections.
WARNING: High Voltage. Bus Bar’s can have voltage 810V
dc
even after switching off
(capacitive voltage). Discharge Time approx. 6 Minutes.
WARNING: High Voltage. The recovery resistor is connected to the Bus Bar’s and can have
voltage 810V
dc
.
WARNING: do not touch recovery resistor during operation to avoid scalds.
5.2.1 CIRCUIT DESCRIPTION
The high power supply consists of four functional blocks:
High voltage rectification and filtering
Soft-start of AC mains power-on
Low voltage control power supply
Recovery circuit