Fault Conditions
53
E-51
Brake contactor fault. P8
input on J2 of EC-MCB.
Check input device.
Check setting of parameter F1-01. Verify that setting matches physical
characteristic of break contact.
E-52
Seismic fault. P24 input on J4
of EC-MCB.
Check input device to terminal P24. User defined error message will be
generated for some software versions if programmed by user.
E-53
Smoke detection fault. P21
input on J4 of EC-MCB.
Check input device to terminal P21.
E-55
Safety circuit fault. P6 input
on J2 of EC-MCB.
Check stop switch on top of control cabinet.
Check remaining safety devices.
E-56
Safety circuit fault. P26 input
on J2 of EC-SCB.
Check stop switch on top of control cabinet.
Check remaining safety devices.
E57 Stopping distance error.
Number of pulses exceeds the learned value by more than the pro-
grammable stopping distance error, See “Escalator Braking Distance
Feature” on page 29 .
E58 Stopping distance error.
Number of pulses is less than the learned value by more than the pro-
grammable stopping distance error, See “Escalator Braking Distance
Feature” on page 29 .
E-59 P37 input on J3 of EC-SCB
Check input device to terminal P37. User defined error message will be
generated for some software versions if programmed by user.
Table 19. Customer Specific Fault Display Assignment Entry
Fault Terminal Your System Assignment
E-10 P10 on EC-MCB
E-11 P11 on EC-MCB
E-12 P12 on EC-MCB
E-13 P13 on EC-MCB
E-14 P14 on EC-MCB
E-15 P15 on EC-MCB
E-16 P16 on EC-MCB
E-17 P17 on EC-MCB
E-18 P18 on EC-MCB
E-27 P27 on EC-SCB
E-28 P28 on EC-SCB
E-29 P29 on EC-SCB
E-30 P30 on EC-SCB
E-31 P31 on EC-SCB
E-32 P32 on EC-SCB
E-33 P33 on EC-SCB
E-34 P34 on EC-SCB
Table 18. Controller Fault Displays