EasyManua.ls Logo

Motorola APX 1000 - Performance Testing; Figure 6-31. Front End Filter Alignment Screen (UHF2)

Motorola APX 1000
526 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Radio Alignment Procedures: Performance Testing 6-23
Figure 6-31. Front End Filter Alignment Screen (UHF2)
6.7 Performance Testing
6.7.1 Bit Error Rate
This section describes the Bit Error Rate (BER) test of the radio’s receiver at a desired frequency
(see Figure 6-32, Figure 6-33, Figure 6-34, Figure 6-35 and Figure 6-36).
6.7.1.1 Bit Error Rate Fields
Set up the R2670 Communication Analyzer as follows:
1. Connect the RF Input port of the radio under test to the RF IN/OUT port of the R2670 Service
Monitor.
2. Set up the R2670 Service Monitor:
- In the Display Zone, select PROJ 25 STD mode and set the meter to RF DISPLAY.
- In the RF Zone, configure the analyzer as follows:
- In the Audio Zone, select the 1011 Hz PAT code and set the deviation to “PROJ25Dev:
2.83 kHz ~”.
The bit error rate screen contains the following fields:
Rx Frequency:
This field selects the Receive Frequency directly in MHz.
RF Control: Generate
Preset: B/W: NB
Freq: Test frequency (Ex: 851.0625 MHz)
Output Level: -50.0 dBm
Gen RF Out: RF I/O

Table of Contents

Other manuals for Motorola APX 1000

Related product manuals