Remote Mounting 29
Connections Plans for Junction Box Terminal
Connection Plan for Speaker
For connecting the speaker to the junction box terminal, see above.
Connection Plan for Alarm Relay
Figure 30 Alarm Relay Connection Plan
Do not short pin 5 of the terminal board to ground, as this may damage the radio.
Connection Plan for Emergency Switch
Figure 31 Emergency Switch Connection Plan
5
5
ALTERNATIVE
ALTERNATIVE
RED
RED
86
87
85 30
BLK
RED
BLK
ALARM
RELAY
+12 V
ALARM
RELAY
86
87
85 30
RED
+12 V
BLK
BLK
5
RED
BLK
BUZZER
+12 V
JUNCTION BOX TERMINAL
!
C a u t i o n
EMERGENCY
SWITCH
JUNCTION BOX TERMINAL