User Preferences & Miscellaneous Digital Imager Scanner Options 4 - 11
Presentation Time Delay Mode
Parameter # F1h, E9h
Use this option to set the time the digital imager scanner enters into in hands-free mode. The default is Disable 
feature. The digital imager scanner will remain in hands-free mode until the trigger is pulled and released at which 
point the digital imager scanner will revert to the current trigger mode setting. If the trigger is unused for the 
duration of the time delay mode, the digital imager scanner will remain in hands-free mode. 
Simulated Scan Base Operation
When using the Digital Imager Scanner with Base (see Figure 1-2 on page 1-1), this parameter is enabled with a 
default of 3 Seconds.
*Disable 
1 Sec
2 Secs
**3 Secs
4 Secs
5 Secs