Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
If the RSTP root has changed
RSTP Topo. Changed
If any Rapid Spanning Tree Protocol switches have changed their position
(applies only to the root of the tree)
Turbo Ring path is disconnected
DI1 (OnOf f ) Digital Input 1 is triggered by an on to of f transition
Digital Input 1 is triggered by an of f to on transition
ABC-02 Status
Detects if the ABC-02-USB-T is connected or disconnected to the switch
when the ABC-02-USB-T automatically imports/exports/backs-up the
Rate Limited On (Disable Port)
When the port is disabled due to the ingress throughput exceeding the
conf igured rate limit.
Rate Limited Of f (Disable Port)
The port disable f unction is of f because it exceeds the traffic duration or
the user changes “Port Disable” mode to “Drop Packet” mode.
Port looping event is triggered
Nearly connected devices are changed and shown in the LLDP table
The attempt to log in exceeds the threshold
Account Info Changed The account information has been changed
Conf iguration is Imported
When the conf iguration is successf ully imported
SSL Certif ication is Imported
When SSL Certif ication is successfully imported
Fiber Check Warning*
If the corresponding value of the fiber port status exceeds the threshold
def ined by the Fiber Check f unction
MAC Sticky Violation Port Disable
Any port with MAC sticky f unction is disabled because of a rule violation
*The Fiber Check Warning event is only supported by EDS-P506E-4PoE, EDS-510E, EDS-518E,
EDS 528E, and EDS-G500E Series.
Four response actions are available on the EDS E series when events are triggered.
The EDS E series will send a notification to the trap server when an event is triggered.
E-Mail The EDS E series will send a notif ication to the email server def ined in the Email Setting.
The EDS E series will record a syslog to syslog server defined in Syslog Server Setting.
Relay
The EDS E series supports digital inputs to integrate sensors. When an event is triggered,
the device will automate alarms through the relay output.
Severity
Severity Description
Emergency System is unusable
Alert Action must be taken immediately
Critical Critical conditions
Error Error conditions
Warning Warning conditions
Notice Normal but signif icant condition
Inf ormation Informational messages