Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
36
Auto backup of event log to prevent overwrite
This f unction is designed to maintain a long-term record of the switchs log files. Moxa Ethernet switches are
capable of saving 1000 event log entries. When the 1000-entry storage limit is reached, the switch will
delete the oldest saved event log. The ABC-02 can be used to back up these event logs. When the number
of switch log entries reaches 1000, the ABC-02 will save the oldest 100 entries f rom the switch.
Enable the Auto backup of event log to prevent overwrite, and then click Apply. Af ter that, when the
ABC-02 is plugged into the switch, the event logs will always be saved to the ABC-02 automatically when
the number of switch log entries reaches 1000. Each backup action saves the oldest 100 logs to the ABC-02
in one f ile, with the f ilename generated by the current system time as MMDDHHmm.ini. The f ile is saved
to the His_log f older.
NOTE
MM=month, DD=day, HH=hour, mm=minutes, f rom the system time.
The log f ile includes the f ollowing inf ormation:
Index
An event index assigned to identify the event sequence.
Bootup Number
This field shows how many times the Moxa switch has been rebooted or cold started.
Date
The date is updated based on how the current date is set on the System Settings page.
Time
The time is updated based on how the current time is set on the System Settings page.
System Startup
Time
The system startup time related to this event.
Event
Events that have occurred.
Switch Reset Button
The Moxa switch reset button can be used to quickly reset the switch’s conf iguration, and save the current
conf iguration and log f iles to the ABC-02. Press the Reset button on top of the EDS switch to back up the
current system conf iguration f iles and event logs to the ABC-02.
NOTE
DO NOT remove the ABC-02 when perf orming an upgrade, backup, or restore.
Turbo Ring DIP Switch
The Turbo Ring DIP Switch page allows users to disable the 4th DIP switch located on the EDS’s outer
casing. The def ault is enabled with Turbo Ring v2 protocol. Once the user changes the 4th hardware DIP
switch conf iguration to ON, the switch will start to initiate the Turbo Ring redundancy protocol based on the
conf iguration. The detailed description is given below:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies IKS-6726A and is the answer not in the manual?

Moxa Technologies IKS-6726A Specifications

General IconGeneral
BrandMoxa Technologies
ModelIKS-6726A
CategorySwitch
LanguageEnglish

Related product manuals