NPort 5600 Series User’s Manual Web Console Configuration
5-29
Reverse Telnet Mode
TCP alive check time
Setting Factory Default Necessity
0 to 99 min 0 Optional
Specifies the time slice for checking if the TCP connection is alive. If there is no response, NPort
5600 series will disconnect the original connection.
Inactivity time
Setting Factory Default Necessity
0 to 65535 ms 0 Optional
Idle time setting for auto-disconnection. 0 min. means it will never disconnect.
Local TCP port
Setting Factory Default Necessity
1 to 65535 4001 Optional
Each of NPort’s serial ports is mapped to a TCP port. To avoid conflicts with TCP ports, set port
numbers to 4001 for port1, 4002 for port 2, etc. (like the default values).
Map <CR-LF>
Setting Factory Default Necessity
CR, LF, or CR-LF CR-LF Optional