Using the Compressed Air Breathing Apparatus MSA
30 AirGo
(4) Open cylinder buckle on the cylinder strap eliminating any tension by
extending the strap to full length pulling the small bar at the buckle
( Fig. 18).
(5) Push compressed air cylinder through the cylinder strap (2) with the cylinder
valve toward the pressure reducer so that it lies on the central support (3).
(6) Align the compressed air cylinder with the alphaCLICK 2 axially to the
coupling and fit on the alphaCLICK 2 coupling.
Attention!
Never push the coupling system together using excessive force.
(7) Close the coupling by pushing together using a "small amount" of force and
checking that the arrow of the indicator ring is vertically aligned with the
back plate.
(8) Tighten cylinder strap gently by pulling the free end.
Attention!
Do not overtighten the cylinder strap! Damage can occur when using
excessive force to close the cylinder buckle and the SCBA might not be
ready for use.
The final fastening tension will be achieved when closing the cylinder
buckle.
(9) Check position of compressed air cylinder, re-position if necessary.
(10) Hinge cylinder buckle (4) gently and completely down over the centre until it
catches.
(11) If push force/tension is too high during hinging of the cylinder buckle,
re-adjust the strap length at the cylinder buckle. If the strap tension is too
low, re-adjust the strap length at the cylinder buckle ( Fig. 19).
(12) Fasten end of the cylinder retaining strap onto Velcro strip.
(13) Briefly open cylinder valve and check for escaping air, retighten if necessary.