Maintenance and Care MSA
40 AirGo
4.2. Maintenance Intervals
Test Intervals for all Countries (except Germany)
Component
Work to be
Performed
Before
use
After use Annually
Every 3
years
Every 9
years
1)
Compressed air
breathing
apparatus
complete
Cleaning X X
Sight, function and
tightness check
X X
Check by user
2)
X
Compressed air
breathing
apparatus without
cylinder and lung
governed demand
valve
Overhaul X
alphaCLICK 2
coupling
Cleaning X
Lubricate X
3)
Check by user X
Compressed air
cylinder with valve
Filling pressure
check
X
Technical expert test
See Operating Manual for compressed air cylinder.
Please observe national rules!
Lung governed
demand valve
See Operating Manuals for lung governed demand valve / full face mask.
Please observe national rules!
4)
1) For SCBA apparatus that are frequently used, we recommend a complete overhaul after
approx. 540 hours. For example, this corresponds to 1080 applications with a duration of 30 minutes.
2) The checks are performed with the respective lung governed demand valves and if required, with the
respective full masks.
3) Lubricate alphaCLICK 2 coupling every 500 coupling cycles at least (see maintenance manual).
4) Rubber components are subject to ageing with varying rates according to local conditions and must
be checked and replaced at regular intervals.