Using the Compressed Air Breathing Apparatus MSA
36 AirGo
3.10. Filling with Quick-Fill
Fig. 23 Filling with Quick-Fill (optional equipment)
1 Quick-Fill coupling
Only applicable to SingleLine Pneumatics.
With the Quick-Fill function, the compressed air cylinder(s) of the breathing
apparatus can be filled during use ( Operating Manual for Quick-Fill).
3.11. Removing the Compressed Air Breathing Apparatus
(1) Remove lung governed demand valve, or full face mask.
(2) Close cylinder valve(s).
(3) Activate flushing mode of lung governed demand valve, releasing all air
pressure.
(4) Open hip belt.
(5) Extend shoulder straps by lifting the slides.
Danger!
Do not throw off compressed air breathing apparatus. This could
damage the valve and any remaining compressed air could escape
suddenly.
This could cause fatal injury to you or to any bystanders.
(6) Remove compressed air breathing apparatus.