CATEGORY 33: FOR CATALYTIC TYPE 1S GENERAL SOLVENTS
To detect the following gases, recalibrate with 0.6% propane
and set the span gas value accordingly:
Amyl alcohol 43 JP-4 41
Butanol (n) 48 Methyl Cellosolve 49
Butyl Acrylate 46 Methyl Ethyl Ketone 52
Cellosolve 42 Methyl Isobutyl Ketone 53
Di isopropylamine 42 Methyl Methacrylate 40
Diethylamine 41 Naphtha, VM&P 53
Ethyl Acetate 43 Octane (iso) 52
Ethyl Acrylate 52 Propyl Acetate 45
Ethyl Benzene 41 Styrene 42
Heptane 42 Xylene 50
Hexene 42
CATEGORY 34: FOR ULTIMA IR METHANE
To detect the following gases, recalibrate with 0.6% propane
and set the span gas value accordingly:
Acetone 86 Isoproponal 25
Butadiene, 1, 3 80 MEK 53
Cyclohexane 14 Methane 50
Ethanol 17 Methanol 14
Ethyl Acetate 34 Methyl Formate 13
Ethylene 95 Propylene 39
Heptane 14 Toluene 64
Hexane 14 Xylenes 53
IsoButanol 20
CATEGORY 35: FOR ULTIMA IR NON-METHANE
To detect the following gases, recalibrate with 0.6% propane
and set the span gas value accordingly:
Butane 31 IsoButane 33
Butyl Acetate 48 IsoButanol 47
Cyclohexane 37 IsoPropanol 52
Cyclopentane 32 Methanol 27
Dimethyl Ether 25 Methyl Formate 35
Ethane 30 Pentane 31
Ethanol 36 Propane 29
Ethylene Oxide 72 Propyl Acetate 51
Heptane 36 Propyl Alcohol 31
Hexane 37 Propylene Oxide 26
2-8

Table of Contents

Other manuals for MSA Ultima Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MSA Ultima Series and is the answer not in the manual?

MSA Ultima Series Specifications

General IconGeneral
DisplayLCD with backlight
Communication PortsRS-485, Modbus RTU
Measurement RangeDepends on sensor connected
AccuracyDepends on sensor connected
Outputsrelays
CertificationsUL