5.10 Waterjet – Flushing from LOP (optional)
Preconditions
☑ LOCAL OPERATION illuminated pushbutton is lit brightly (local operating mode is active).
☑ Vessel is at a standstill and waterjet bucket is below the waterline.
☑ Engine speed is in engagement window.
☑ No external engagement interlock is active.
NOTICE
Waterjet flushing puts excessive strain on the bearings.
Bearing damage!
• Do not flush waterjet for too long.
• Follow instructions of the waterjet manufacturer.
Flushing with reversing gearbox and flushing mode
Item Measure
LOP Press FLUSH illuminated pushbutton and keep pressed (→ Page 35).
• FLUSH pushbutton flashes.
• Gearbox is engaged astern.
• After receiving the feedback signal from coupling, the FLUSH pushbutton
is illuminated brightly.
LOP Release FLUSH illuminated pushbutton.
• FLUSH pushbutton flashes.
• Gearbox is disengaged (neutral position).
• Illumination of FLUSH pushbutton is switched off as soon as the feedback
signal from coupling is received.
MW15409/04E 2015-08 | Operation | 45
TIM-ID: 0000002330 - 006