EasyManua.ls Logo

MTU 16V2000M91 - Emergency engine shutdown at LOP (without BlueLine automation system)

MTU 16V2000M91
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.13 Emergency engine shutdown at LOP (without BlueLine
automation system)
NOTICE
An emergency stop causes extreme stress to the engine plant.
Risk of overheating, damage to components!
Initiate emergency stop only in emergency situations.
Emergency engine shutdown from LOP
Item Action
LOP Open cap of illuminated pushbutton EMERGENCY STOP (→ Page 35).
LOP Press illuminated pushbutton EMERGENCY STOP.
Engine is stopped by disconnecting the power supply to the ECU;
On engines with emergency air-shutoff flaps: flaps close;
Illuminated pushbutton EMERGENCY STOP flashes. Horn, flashing lamp
etc. are tripped.
After emergency engine shutdown from LOP
Item Action
LOP Press illuminated pushbutton ALARM ACKNOWLEDGE (→ Page 35).
Audible and visual alarm signaling stops.
LOP Press illuminated pushbutton ALARM ACKNOWLEDGE again.
Power supply to ECU is provided;
Alarm has been acknowledged.
Engine On engines with emergency air-shutoff flaps: open flaps.
Engine is ready for starting.
48 | Operation | MW15409/04E 2015-08
TIM-ID: 0000002313 - 004

Table of Contents

Related product manuals