2. Open threaded vent plug (1) of contaminated
filter.
3. Unlock drain valve (5) by pressing toggle and
open it.
4. Drain water and dirt from filter.
5. Close drain valve (5).
6. Remove screws securing cover (2) and take
off cover.
7. Remove spring cartridge (3) and filter ele-
ment (4).
8. Insert new filter element (4) and spring car-
tridge (3).
9. Fill filter housing with clean fuel.
10. Place new seal in cover.
11. Fit cover with gasket and secure it with
screws (2).
12. Cut in the cut-out filter again.
13. Close threaded vent plug (1) when fuel
emerges.
14. Set differential pressure display instrument
(→ Page 92).
98 | Task Description | MW15409/04E 2015-08