Configuring the job computer
Configuring the nozzles - for sprayers with pressure calculation
52
V1.20190404
3030383000-02-EN
4. In the “Results” area, you can see the speed at which the application rate can be achieved.
Calibrate the nozzles
“Calibration” screen
Selected nozzle
Nozzle output at 3 bar - Result of the
calibration
Current nozzle output. When you change the
pressure, the newly calculated nozzle output
appears.
For non-standard nozzles, the calibration must
be repeated at a different pressure. This
pressure should be about as high as the
intended working pressure.
WARNING
Spray liquid or spray liquid residues
Danger of poisoning or chemical burning
Clean the spray liquid tank thoroughly prior to calibration. The sprayer must be free of spray
liquids or spray liquid residues.
Use only clear water during calibration.
Wear required protective equipment.
Calibrate a standard nozzle as follows:
The tank is filled with clear water.
There are no spray liquid residues in the tank or the pipelines.
1.
- On the work screen, switch the application mode to manual.
2.
- Start application
3.
and - Set the spray pressure to 3 bar.
4. Using a measuring cup, collect the water from several nozzles for one minute each.
7.6.2
Illustration
Procedure