Troubleshooting
Alarm messages
8
Troubleshooting
Alarm messages
Sprayer
The volume of spray liquid in the tank has fallen below the “Tank level alarm”.
SPRAYER
Alarm appears when a sensor detects a certain oil level. The oil level depends on the
implement manufacturer and the installation of the sensor.
The implement is being operated
using an external device! To cancel,
The sprayer is currently not being operated using the terminal, rather via an external input
device. To terminate the external operation, acknowledge the alarm. You will then be able
to operate the controls again.
Spray regulation
SPRAY REGULATION
The system cannot adjust the application rate to the rate.
SPRAY REGULATION
The minimum spray pressure could not be reached. Parameter: Min. pressure
SPRAY REGULATION
The pressure is too high.
Pressure is higher than defined in the parameter. Parameter: Max. pressure
L/min too high, above flow meter
Flow is too high. The flow meter is not capable of measuring reliably.
L/min too low, below flow meter
Flow is too low. The flow meter is not capable of measuring reliably.
System
To change the parameter, the
password must first be entered.
The function that you want to perform is only available after entering the password.
Checking the software version
To find out the software version:
1. Switch to the “PARAMETERS” screen:
> > > >
⇨ The software version will be shown.