Video Grabber User Manual - v. 1.19 (FW 1.29)
I-Frame period for H264 and
Lossless encoders – setting it to 50
makes every 50
th
frame an I-
Frame.
Used for analog signal filtering. If
two consecutive frames are
compared and the difference
between Red, Green and Blue
components of the pixel do not
exceed this value then such pixels
are considered identical.
Min: 0
Max: 31
Bandwidth limiter:
0 – disabled
1 – enabled
Bandwidth limit warning level in
kilobits per second
codecLlBwLimit
WarnTimeToDrop
If codecLIBwLimitWarnLevel is
exceeded more than amount of
seconds set here then frames will
be dropped to keep bandwidth
below the limit
codecLlBwLimit
CriticalLevel
Bandwidth limit critical level in
kilobits per second. If exceeded
then FPS is lowered.
Bitstream compatibility mode:
0 – specification 2.0
1 – specification 2.1