Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 34
Serial Commands – Setup
Command Syntax set serial [s0/s1] chat-script <line-num> <expect-string> <send-string>
Description
Sets expect and send strings for the chat script to act on the modem.
Triggers for a reboot upon save.
Important Note:
Use double quotes if more than one word is used in the
<expect-string>/<send-string>.
Default Value
NA
Success
OK
Error 1. Too few arguments
"Usage: set serial s0/s1 chat-script <line-num> <expect-string> <send-string>
Type 'set serial s0/s1 chat-script ?' for more information"
Command Syntax Set serial [s0/s1] connect-type <direct/modem>
Description
Sets the connect type of the serial port to direct/modem connect.
Note: Modem port (S1) will always have connect-type as modem since it is a
built-in modem
Default Value
Direct
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 connect-type <direct/modem>
Type ‘set serial s0/s1 connect-type ?’ for more information”
2. Invalid string
“error: Invalid string
Type ‘set serial s0/s1 connect-type ?’ for more information”
3. If “set serial s1 connect-type direct” is given
error: modem port s1 is a built-in modem interface; it cannot be set to direct
Command Syntax set serial [s0/s1] connect-state <answering/dialing/both>
Description
Sets the connect state of the serial port to answering/dialing/both state.
Default Value
Both
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 connect-state <answering/dialing/both>
Type ‘set serial s0/s1 connect-state ?’ for more information”
2. Invalid string
“error: Invalid string
Type ‘set serial s0/s1 connect-state ?’ for more information”
Command Syntax set serial [s0/s1] data-bits <7/8>
Description
Set the data-bits.
Default Value
8
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 data-bits <7/8>
Type ‘set serial s0/s1 data-bits ?’ for more information”
2. Invalid data-bit setting
“error: Data-bits range supported: [7/8]
Type ‘set serial s0/s1 data-bits ?’ for more information”