-24-
8.8. Average Params
Menu Function Value Function Description
Ordinal Number in the "Average" Hot Menu
Reset Trip Forced clearing of average parameters per trip
Reset Reset1 Forced clearing of average parameters in the "Display Average/Reset1"
Reset Reset2 Forced clearing of average parameters in the "Display Average/Reset2"
Reset Logs Forced clearing of the average log and refuelling log.
Time cost 1h 0...99,9
Dist.cost 1km 0...99,9 The cost of the trip per 1 km
Petr.cost 1l 0...99,9 The cost of 1 litre of fuel
AutoReset1
AutoReset2
Continuous Trip
Show trip
Auto Log
Trip Log Trip log management ("Display Average/Trip" data)
Continue
Save
View View the trip log.
Petrol log Trip log from refueling to refueling (data from the "Display Average Reset2/Refueling")
№
The cost of 1 hour trip
(CU)
The cost of the trip per 1 hour. Еstimated in conventional units, i.e. rubles, hryvnia, dollars, etc.
(UE - conventional units)
The cost of 1 km trip
(CU)
The cost of 1 liter of
fuel (CU)
Automatic Reset
Period
>manual
1...99 day
After the set period of time, the parameters in the "Average Display/Reset1" automatically reset".
When setting "Manual", the parameters reset manually (menu selection "Reset Trip").
Automatic Reset
Period
>Fefuel.
Man.
1...99 day.
Reset the parameters in the "Display Average/Reset2" (from refueling to refueling).
Refuel. - reset when refueling (changing the amount of fuel in the tank). For "Tank FLS ECU" -
with an increase of about 20% of the volume of the calibrated tank; for "Tank Calculated" - with
any positive change.
The duration of
continuous trip
(min)
0...995
>0
Calculations in the "Display Average/Per trip" do not interrupt if the engine is stopped less than
the entered time period.
Forced continuation of the trip - "Trip log - Continue" (see below).
Switching to the
"Display Medium
/Trip" after the engine
stops
>--
Yes
When "Yes" is set, each time the engine stops, the display automatically switches to the "Display
Average/ Trip" for 5 seconds .
Automatic trip log
recording
>On.
Off.
When "On" is set, all trips are recorded in the log automatically, otherwise the recording is
possible only in the manual mode. For correct performance, set the current time and date.
No
Yes
To forcibly continue calculation of the average parameters for the trip, it is necessary, without
starting the engine and turning on the ignition, to select the "Yes" option with the "SET" button
and start the engine.
Manual recording of average parameters per trip in the trip log when automatic recording is
disabled. A short press on the "SET" button displays a list in the format "No. time date"; the
average parameters can be saved in an empty cell or replaced with existing ones.
8.9. HotLists clear.
Menu Function Description
Parameters The "Hot Menu Parameters" cleanup. Pres SET to confirm, ESC to escape.
Average The "Hot Menu Average" cleanup.