EasyManua.ls Logo

multivac C200 - User Manual

multivac C200
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Language: English (EN) - Original operating manual
Order number: C200-P-WO-0000020.16-EN-ER
Instruction manual
Chamber machine C200
MC06
Serial number:
.........................................................
Service address: Manufacturer:
MULTIVAC
Sepp Haggenmüller GmbH & Co. KG
Bahnhofstraße 4
D-87787 Wolfertschwenden, Germany
Tel.: 0049 8334 601 0
www.multivac.com
Date: 03.06.2014
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is
prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.

Table of Contents

Questions and Answers

  • S
    Shelly ColeSep 12, 2025
    What to do if the ventilation valve does not open on my multivac C200 Kitchen Appliances?
    • J
      Jonathan WilkersonSep 12, 2025
      If you are experiencing issues with your Multivac Kitchen Appliances related to the vacuum pump not switching off, ventilation valve not opening, vacuum sensor being incorrectly calibrated or defective, gas valve not opening, or the evacuation system leaking, notify the service.
  • A
    Aaron ChangSep 12, 2025
    What to do if the vacuum pump does not switch off on my multivac C200 Kitchen Appliances?
    • N
      Nathan EvansSep 12, 2025
      If you are experiencing issues with your Multivac Kitchen Appliances related to the vacuum pump not switching off, ventilation valve not opening, vacuum sensor being incorrectly calibrated or defective, gas valve not opening, or the evacuation system leaking, notify the service.
  • W
    William HowardSep 9, 2025
    How to resolve insufficient oil quantity in my Multivac Kitchen Appliances?
    • D
      David GardnerSep 10, 2025
      If there is insufficient oil quantity or the oil in the vacuum pump of your Multivac Kitchen Appliances is too old, refill or replace the oil.
  • C
    Cody SolisSep 8, 2025
    What to do if products give off steam during evacuation in my multivac C200?
    • H
      Heather HillSep 9, 2025
      If you observe moist or liquid products giving off steam during the evacuation process of your Multivac Kitchen Appliances, abort the evacuation process with the key in case the chamber lid mists up. Pack product with the Automatic function and set the value for the Automatic sensitivity.
  • S
    Sarah ReynoldsSep 7, 2025
    How to replace chamber lid gasket on my Multivac Kitchen Appliances?
    • M
      Mallory HopkinsSep 8, 2025
      If the chamber lid gasket is damaged on your Multivac Kitchen Appliances, change the chamber lid gasket.
  • T
    theresa27Aug 23, 2025
    What to do if my multivac C200 pack is leaking?
    • C
      Christopher GarrettAug 23, 2025
      If your Multivac Kitchen Appliances pack is leaking, there could be several reasons: * The sealing time might be set incorrectly, so increase the value for sealing time in small increments. * The pouch neck might be clamped by the chamber lid. Ensure the film pouch is inserted so that the pouch neck lies within the chamber, and cut off the pouch neck if necessary. * The seal seam might be dirty, so keep the inside of the film pouch clean in the area of the seal seam. * The film pouch could be damaged; use a new one. * The film pouch might not be suitable for sealing; use a film pouch suitable for sealing.
  • T
    Travis GonzalezSep 5, 2025
    What to do if the pouch neck is clamped by the chamber lid in my Multivac Kitchen Appliances?
    • S
      Sarah BlevinsSep 5, 2025
      If the pouch neck is clamped by the chamber lid on your Multivac Kitchen Appliances, insert the film pouch so that the pouch neck lies within the chamber. Cut off the pouch neck if necessary.
  • M
    Mark DixonSep 4, 2025
    How to adjust gas flushing time on my multivac C200 Kitchen Appliances?
    • H
      Henry CrawfordSep 4, 2025
      If the gas flushing time is set too high on your Multivac Kitchen Appliances, reduce the gas flushing time value.
  • J
    Joseph Burke Jr.Sep 3, 2025
    How to adjust gas flushing pressure on my multivac C200?
    • M
      Mr. Brady Holmes IISep 3, 2025
      If the gas flushing pressure is set too high on your Multivac Kitchen Appliances, reduce the gas flushing pressure value.
  • J
    Jeffrey HowardSep 2, 2025
    How to fix poor vacuum in my multivac C200 pack?
    • A
      alicia30Sep 2, 2025
      To resolve the issue of poor vacuum in the pack with your Multivac Kitchen Appliances, reduce the evacuation pressure value.

Summary

Safety

General Safety Instructions

Provides fundamental safety guidelines, target user qualifications, and responsibilities.

Intended Use

Specifies the machine's designated purpose and limitations for safe operation.

Reasonably Foreseeable Incorrect Use

Details prohibited operational methods that deviate from intended use.

Warning Against Incorrect Use

Highlights consequences of neglecting operational procedures and maintenance.

Obligations of the Operating Company

Outlines legal and operational duties for the machine operator.

Description

Control Terminal

Explains the function of keys and display elements on the control panel.

Start-Up

Setting Up the Machine and Starting It Up

Step-by-step guide for initial machine placement, connection, and power-on.

Operation

Switching On the Machine

Procedure for powering up the machine and initiating its operational readiness.

Switching Off the Machine

Steps to safely power down the machine and perform post-operation tasks.

Packing Products

Detailed instructions on how to place and pack products for vacuum sealing.

Recipe Management

Guides on loading, saving, and deleting product-specific recipes.

Cleaning

Maintenance

Maintenance Schedule

Overview of recommended maintenance tasks and their frequencies.

Maintenance Recommendation

Detailed procedures for routine checks and component upkeep.

Troubleshooting

Malfunctions with Diagnostic Message

Lists symptoms, causes, and solutions for machine errors indicated by diagnostic codes.

Faults Without Diagnostic Message

Identifies common issues and their remedies when no diagnostic code is displayed.

Shutdown, Transport, Storage

Disposal

multivac C200 Specifications

General IconGeneral
Product TypeVacuum Sealer
ModelC200
Sealing MethodHeat Sealing
Vacuum Power0.8 bar
Bag WidthUp to 300 mm
Voltage220-240 V
Frequency50/60 Hz
MaterialStainless Steel
Additional FeaturesBuilt-in cutter