Having the correct feeding gap adjusted will ensure a smooth counting as well as a trouble-free operation. Trial
and error attempts are recommended before you make the final adjustment and start the count.
You may also perform this adjustment when the banknotes are not fed smoothly through the machine or several
error messages are occurring too often like Bill Double Error, Chain Notes Error or Half Notes Error.
Other reasons that might require to readjust the feeding gap are:
- The counting of new or mint condition notes
- The counting of poor or bad fitness condition notes
- Polymer notes and Paper-made notes counted together
7.5. CIS Calibration
CIS calibration is needed when there are many errors during the banknote counting process.
1) Please enter the menu interface. And go to the service menu with the password 9999”, as shown in the
following figures.
Figure 7-18 Main Menu
Figure 7-19 Service Menu
2) Click the CIS Calibration” option, the screen will be shown in the following figure.
Figure 7-20 CIS Calibration Interface
3) Open the back cover to clean the CIS sensors with cleaning cloth.