© Munters AB, 2020 43
In this example Fan 1operates according to the levels determined by the temperature and day,
beginning at Level 1. The fan will supply up to 10% of the possible ventilation. At Level 4, Fan 2
also begins to operate, supplying up to 40% of the possible ventilation. Under each ventilation
level, Trio displays the total fan capacity of the fans operating.
Each level shows the maximum possible ventilation capacity. In this example, each fan has a
capacity of 5000 M3/h. At Level 1 this means that the maximum is 50000 M3/h and at Level 4
10,000 M3/h.
9.2.2
F
AN
O
PTIONS
The following sections shows examples of different ventilation options.
•
Minimum Ventilation Cycle: Minimum Ventilation Cycle: Fans run in an on/off cycle with user-
defined times.
•
Analog Fans: Fan speed changes as ventilation requirements change.
•
Fans (Efficiency Fan): Fan runs at a maximum speed percentage defined by the user.
•
Fan Rotation: Different fans running in Minimum Ventilation Cycle can be designated to run in
rotation.