© Munters AB, 2020 72
14
Timers
Timers provide an additional method of controlling relay devices, namely setting a timetable in which the
device can operate. In addition to the timetable, Trio enables setting up time cycles and temperature
ranges in which a device can operate.
Trio supports up to five timers.
Define at least one relay as a timer. Refer to the Installation Manual.
1. In Control > Timers, click edit, define a timer as Active.
2. Define for each timer:
o
Active House Mode: Define in which mode each timer can operate. Multiple modes can
be selected. Note: This option is not available for Central Exhaust or Central Corridor
setups.
o
Time: Timers can run 24 hours a day or in user-defined time frames. Define up to four
time frames for each timer.
o
Cycle: If enabled, define the cycle times. Range: 0 999 seconds.
o
Temperature: If enabled, define the temperature range in which the timers operate.
Range [-40° - +90°].
3. As an option, timers can be mapped to an outside temperature sensor. Go to System >
Temperature Definition.

Table of Contents

Other manuals for Munters Rotem Trio

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Munters Rotem Trio and is the answer not in the manual?

Munters Rotem Trio Specifications

General IconGeneral
BrandMunters
ModelRotem Trio
CategoryFarm Equipment
LanguageEnglish

Related product manuals