© Munters AB, 2020 75
Alarm delay: After detecting that a parameter has gone above or below its specs, Trio waits
this amount of time before sending an alarm. This prevents sending alarms for short deviations.
Range: 0 999 seconds.
Alarm Reminder: Trio will resend an alarm after this amount of time if the alarm is not
acknowledged. Range: 0 999 minutes.
Water Overflow Max Water/Hour: Trio sends an alarm if the water flow exceeds this amount.
Water Shortage:
o
Min Water/Hour: Trio will send an alarm if the water flow is less than this amount.
Range: 0 999 gallons/liters.
o
Enable Water Shortage Alarm: Define the period in which the alarm is active, 24 hours a
day or specific time frames.
Potentiometer: Enable Potentiometer Alarm: Trio will send an alarm if potentiometer-controlled
inlets are not opening to the required levels. Define the period in which the alarm is active, 24
hours a day or specific time frames.
15.1.2
A
LARM
T
EST
The alarm test confirms that the alarm system is functioning properly. A test can be performed manually at
any time or scheduled weekly or daily.
Manual Test
Scheduled Tests
15.1.2.1
Manual Test
Click . Stop the test as needed.
15.1.2.2
Scheduled Tests
Scheduled tests can be performed once a day only.
1. On the Alarm Screen, enable Scheduled Alarm Test.
2. Define the day(s) and time at which the test is performed.

Table of Contents

Other manuals for Munters Rotem Trio

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Munters Rotem Trio and is the answer not in the manual?

Munters Rotem Trio Specifications

General IconGeneral
BrandMunters
ModelRotem Trio
CategoryFarm Equipment
LanguageEnglish

Related product manuals