9.2.2.1
Minimum Ventilation Cycle
1. Go to Climate > Ventilation > Settings.
2. Define:
o
Total Cycle Time (sec): Define the minimum ventilation cycle time. Range: 60 999
seconds.
o
Min Cycle Off Time (sec.): When using cycle time, Trio automatically adjusts the ON time
set in the main screen. This parameter defines the minimum cycle off time. Range: 0
600 seconds.
3. System > Control Strategy > Ventilation .
4. Enable Minimum Ventilation Cycle.
5. Go to Climate > Ventilation. The (Fan) On time appears on the screen.