9.4.3
T
UNNEL
D
OORS
In Tunnel Ventilation, Trio
enables control over the tunnel doors using control by level or control by static
pressure. Control of these doors is the same as control over inlets. Refer to these sections for details.
Level Control
Static Pressure Control
9.5
Calibrating the Inlet/Tunnel Door
To ensure that air circulation is carried out in the most efficient manner and according to the
specifications, inlets must be positioned (opened) accurately. If used, a potentiometer can control the
opening and closing with a high degree of precision.
However when there is no potentiometer, positioning accuracy tends to degrade after the inlets go
through several opening and closing cycles. The following section describes how to recalibrate the inlets,
using a potentiometer or without a potentiometer.
During installation, the user enables auto-calibration in digital output inlets. Calibration automatically
takes place after the number of inlet movements equals the number of movements required to start
calibration.
Only one inlet or tunnel curtain can be calibrated at a time.
Relay open occurs when the target position is 100%.
Relay close occurs when the target position is 0%.
1. Go to System > Control Strategy > Ventilation .

Table of Contents

Other manuals for Munters Rotem Trio

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Munters Rotem Trio and is the answer not in the manual?

Munters Rotem Trio Specifications

General IconGeneral
BrandMunters
ModelRotem Trio
CategoryFarm Equipment
LanguageEnglish

Related product manuals