EasyManuals Logo

Murphy Selectronic TTD Series User Manual

Murphy Selectronic TTD Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Section 50 00-02-0329
01-09-07 - 46 -
Specifications
Power Requirements:
PSU-2: 10-32VDC, 10W (max); 90-400VDC CD Ignition, 750uA @ 100VDC (max)
On-Board Backup Power: Lithium battery, 6 VDC, 1300 mAh.
Digital Inputs: 48 (a.k.a. Channels)
Sensor Types: Discrete Input, N.O./N.C., intrinsically safe or nonincendive
Magnetic Pickup Input:
One Magnetic Pickup Sensor Input: 3.6 - 120 VAC, 2-10 kHz.
Outputs:
IGN: 0.4A @ 400VDC(*) for 5 seconds
0.15A @ 400VDC(*) cont. duty
FV- : 0.5A @ 400VDC(*) cont. duty
ALR: 0.5A @ 48VDC
AUX: 0.5A @ 48VDC
(*) CSA approval for 250VDC maximum pending.
Operator Interface:
Display Type: LCD, Static, 80 segment, custom text with LED Backlight
Display Viewable Area: ~ 2.79 x 1 in. (71.04mm x 25.4mm)
Display Contrast: Automatic
Display Backlight: Yellow (Normal Operation); Red (Shutdown)
(Backlight will only be available when unit is powered by DC or AC.)
Voltage Level Monitor: Monitor and display voltage level of DC Supply, CD Ignition, and internal battery.
Keypad: 6 switches: Ridge Embossed, Metal Dome, Tactile 14 Oz. Trip Force
Enclosure Cutout: 5.25 x 5.25 inches (133 mm).
Operating Temperature: -40 to +85 degrees C
Viewable Temperature: -40 to +85 degrees C
Storage Temperature: -40 to +85 degrees C
Tachometer Accuracy: ±0.5% of the display reading or ±1 RPM, whichever is greater.
Resetable Hourmeter Range: 0 to 65535 hrs.
Non-Resetable Hourmeter Range: 0 to 65535 hrs.
Hourmeter Accuracy: ±1 hour per year.
Communication Ports: 1
A single bi-color (GREEN/RED) LED is provided to give visual indication of active transmit and receive traffic. Only one
connection will be active at any time.
Interface: Factory configured for RS485; field-selectable for RS232 or RS485.
Baud/Configuration: 9600, 19.2K, 38.4K(**);N,8,1;N,8,2
Protocol: Modbus (Slave)
Connection: There are 2 screw terminal connectors for RS485.
There are 2 screw terminal connectors for RS232.
There is 1 screw terminal common for both ports labeled as GND.
(**) 38.4K Baud will not be available when IGN input is selected as the source for RPM calculations. When MPU is selected,
this feature is available for selection.
Third Party Approvals Pending:
TTD-H, PSU-2: CSA Class I, Division 2, Groups B, C, and D.
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com