Section 50 00-02-0329
01-09-07 - 19 -
Fault Codes
Fault Codes Description
1-48
Indicates the input that has faulted or alarmed
49
Loss of Ignition (When the CD ignition falls below 90 VDC± 10%,
the firmware activates the fault)
50
Overspeed
51
Underspeed
52
Manual Stop
53
Low Device Voltage (internal diagnostic)
54
Crystal Failure (internal diagnostic)
60
Watchdog Timer
61
Loss of SPI Link
62
Low DC Voltage (Alarm)
63
Low Backup Battery (Alarm)
Backlight used as Status Indication
If AC or DC power is connected the backlight functionality is implemented on Div. 2 power
supplies.
Run Mode – The backlight will be yellow under this condition.
Shutdown Mode – The backlight will turn red under this condition. When a shutdown fault is
detected, the backlight will blink. The backlight blinking will continue for 5 minutes, and can be
aborted if the user presses any key. After 5 minutes, the backlight stays red. During manual
shutdown sequence the backlight will be red.
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Murphy Selectronic TTD Series and is the answer not in the manual?

Murphy Selectronic TTD Series Specifications

General IconGeneral
BrandMurphy
ModelSelectronic TTD Series
CategoryControl Unit
LanguageEnglish

Related product manuals