6. MESSAGE STRUCTURE
All PGNs are shown as module congured with no jumpers (Oset = 0)
PGN
61408(0xEFE0)Node oset of 0
Source Address
(0x??(CSA*))
PDU Format
239(0xEF)
PDU Specic
224(0xE0)
Built Message
(0x18EFE0??)
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Value
82(0x52h)
Name Data Type Byte Bits Description
Command Byte 1 Commandforindexpointer(whichmessageyou’resending)
CtrlModeReset
2 bit
2
1,2 EnablesControllerModeOutputReset
Enable Status 1
Msg
3,4 Enablestheconstanttransmissionofstatusmessage1
Enable Status 2
Msg
5,6 Enablestheconstanttransmissionofstatusmessage2
EnableAmpMsg 7,8 Enablestheconstanttransmissionofamperagemessages
Enable24vdc
3
1,2 Enablesthelowandovervoltagefaultlimitsfor24VDCsystem
SaveCongura-
tion
3,4
Savesthecongurationtothemodule(otherwisechangesonlyvaliduntilapowercycleoccurs),
setto1towritecongurationtomodule
5,6
7,8
4
1,2
3,4
5,6
7,8
FREQ1 Word 5 1,2 Setsthecongurationofthefrequencyforallchannels(30-1140Hz)
6 3,4
MODE1
4 Bit
7 5,6
SetsthecongurationofALLtheoutputs,overidesCommand53and54.(0=Mode1NotUsed,1=ON/
OFF,2=Data0-4000,3=Percent0-100.0%(0-1000),4= Amps (0-4000ma) Can't be used in this mode.
MODE2 7 7,8
Setsthecongurationoftheinputs.(0=Mode2NotUsed,1=DigitalPositive,2=DigitalGround)
No analog
ID1 Byte 8 UserdenedbyteforcongurationID,thiswillbetransimittedintheSTATmessage.
J1939OutputConguration1
*CSA=ControllerSourceAddress