A Murrelektronik Company
35
5.4.1 MODULE STATUS
Status Message 1 (Software and Node Status)
PGN Name Data Type Byte Bits Description
(0xEF(CSA))* SoftwareVersion
Byte
1 Versionofthecurrentsoftware
SoftwareRevision 2 Revisionofthecurrentsoftware
Status 1
2 Bit
3
1,2 FactoryDefaultConguration
Status 2 3,4 CongurationSaved(moduleiscongured)
Status 3 5,6 AlternateCongurationReceived
Status 4 7,8 NodeAlive
Status 5
4
1,2 NodeFaultPresent
Status6 3,4 FaultCountnotZero
Status7 5,6
Status8 7,8
FaultCode
Byte
5 Activefaultcode
User ID 6 TheUserIDofthemoduleconguredinCTRL1message
Status9
2 Bit
7
1,2 TruewhenMessageCommand=0x52hreceived
Status 10 3,4 TruewhenMessageCommand=0x53hreceived
Status 11 5,6 TruewhenMessageCommand=0x54hreceived
Status 12 7,8 TruewhenMessageCommand=0x55hreceived
Status 13
8
1,2 TruewhenMessageCommand=0x56hreceived
Status 14 3,4 TruewhenMessageCommand=0x57hreceived
HardwareVersion 4 Bit 5,6,7,8 Versionofthecurrenthardware
*(0xEF(ControllerSourceAddress))