Value
85(0x55h)
Name Data Type Byte Bits Description
Command
Byte
1 Commandforindexpointer(whichmessageyou’resending)
Port2BKp 2 Output2Bproportionalsetpoint(0-250=0-2.50,>250=0)default 100
Port2BKi 3 Output2Bintegralsetpoint(0-250=0-2.50,>250=0)default 100
Port3AKp 4 Output3Aproportionalsetpoint(0-250=0-2.50,>250=0)default 100
Port3AKi 5 Output3Aintegralsetpoint(0-250=0-2.50,>250=0)default 100
Port3BKp 6 Output3Bproportionalsetpoint(0-250=0-2.50,>250=0)default 100
Port3BKi 7 Output3Bintegralsetpoint(0-250=0-2.50,>250=0)default 100
Notused 8
J1939OutputConguration4
Value
86(0x56h)
Name Data Type Byte Bits Description
Command
Byte
1 Commandforindexpointer(whichmessageyou’resending)
Port4AKp 2 Output4Aproportionalsetpoint(0-250=0-2.50,>250=0)default 100
Port4AKi 3 Output4Aintegralsetpoint(0-250=0-2.50,>250=0)default 100
Port4BKp 4 Output4Bproportionalsetpoint(0-250=0-2.50,>250=0)default 100
Port4BKi 5 Output4Bintegralsetpoint(0-250=0-2.50,>250=0)default 100
Notused 6
Notused 7
Notused 8
J1939OutputConguration5