Note Gap-filling thermal interface materials between the components and
pedestals confined to within the indicated region are allowed to violate the primary
side maximum component height keepaway restrictions.
Note Pedestals of the same dimensions are allowed to have 0.5 mm (0.02 in.)
rounds and 2° draft angles.
Additional Resources for Managing Thermal Conditions
Visit ni.com/info and enter the Info Code sbriocooling for the following additional
information to help you manage thermal conditions:
Examples regarding the effect of the design factors discussed in this chapter
Case study examples to help you estimate the achievable external ambient temperature
for a representative system
Shock and Vibration
The mounting method you use, components you select, and assembly techniques you use
influence the ability of the system to resist fretting corrosion and other damage caused by
exposure to shock and vibration. Consider the following factors when designing your
sbRIO-9607 system to account for shock and vibration:
In general, shorter SEARAY stack heights perform better than taller stack heights.
Directly mounting the thermal solution to a rigid surface provides the best performance.
If this method is not feasible for your design, minimize the amount of extra mass that
only the sbRIO-9607 supports, such as a heat sink or other thermal solution, that is
fastened to the four standoffs. If you require substantial thermal solutions, provide
additional structural support.
NI recommends that you use connectors that provide the following benefits:
Positive locking
Provisions for strain relief
Substantial gold plating on pins
The sbRIO-9607 has been tested to industry specifications for rugged environments.
NI offers a variety of cable assemblies and other connectivity accessories to complete
your system design. Typically, these accessories include the best available designs,
materials, and plating to maximize performance and longevity in rugged environments.
Ports and Connectors
The sbRIO-9607 provides the following ports and connectors.
NI sbRIO-9607 User Manual | © National Instruments | 17

Other manuals for National Instruments sbRIO-9607

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments sbRIO-9607 and is the answer not in the manual?

National Instruments sbRIO-9607 Specifications

General IconGeneral
BrandNational Instruments
ModelsbRIO-9607
CategoryComputer Hardware
LanguageEnglish

Related product manuals