Table 23. sbRIO-9607 Startup Options
Startup Option Description
Force Safe Mode Rebooting the sbRIO-9607 with this setting on starts the sbRIO-9607
without launching LabVIEW Real-Time or any startup applications. In
safe mode, the sbRIO-9607 launches only the services necessary for
updating configuration and installing software.
Enable Console
Out
Rebooting the sbRIO-9607 with this setting on redirects the console
output to the RS-232 serial port. You can use a serial-port terminal
program to read the IP address and firmware version of the sbRIO-9607.
Use a null-modem cable to connect the RS-232 serial port to a computer.
Make sure that the serial-port terminal program is configured to the
following settings:
115,200 bits per second
Eight data bits
No parity
One stop bit
No flow control
Disable RT
Startup App
Rebooting the sbRIO-9607 with this setting on prevents any LabVIEW
startup applications from running.
Disable FPGA
Startup App
Rebooting the sbRIO-9607 with this setting on prevents autoloading of
any FPGA application.
Enable Secure
Shell (SSH)
Logins
Rebooting the sbRIO-9607 with this setting on starts sshd on the
sbRIO-9607. Starting sshd enables logins over SSH, an encrypted
communication protocol.
Note Visit ni.com/info and enter the Info Code openssh for
more information about SSH.
LabVIEW Project
Access
Rebooting the sbRIO-9607 with this setting on enables you to add the
target to a LabVIEW project.
Configuring FPGA Startup App
Use the RIO Device Setup utility, which you can launch in the following ways, to select an
FPGA startup application:
(Windows 8) Click the NI Launcher tile on the Start screen and select RIO Device
Setup.
(Windows 7 or earlier) Select Start»All Programs»National Instruments»RIO Device
Setup.
46 | ni.com | NI sbRIO-9607 User Manual