Table 17. Simultaneous Sampled AI Gain Configuration
Gain_A Contact Gain_B Contact Gain Input Range
open open x1 ±10 V
closed open x2 ±5 V
open closed x3 ±3.33 V
closed closed x4 ±2.5 V
Table 18. DIP Switch Reference Designators and Contact Assignments
GPIC Input Switch Reference Designator Gain_A Contact Gain_B Contact
AI0± SW9 3 4
AI1± SW9 1 2
AI2± SW8 3 4
AI3± SW8 1 2
AI4± SW6 3 4
AI5± SW6 1 2
AI6± SW5 3 4
AI7± SW5 1 2
AI8± SW4 3 4
AI9± SW4 1 2
AI10± SW3 3 4
AI1 SW3 1 2
AI12± SW2 3 4
AI13± SW2 1 2
AI14± SW1 3 4
AI15± SW1 1 2
Note For analog inputs that are connected to inverter current or voltage outputs,
the gain should be set to x1.