3-70 Service Level Troubleshooting
Communication Interface Modes
The Configuration Menu gives the user the option of setting the printer to use a USB
communication.
RS–232C Interface Settings [Standard Model]
If the user sets the printer to use an RS–232C serial interface, the Configuration Menu
can be used to set the following RS–232C specific settings:
Set a baud rate 115200, 57600, 38400, 19200, 9600 baud
Set the number of data bits to seven or eight
Set the number of stop bits to one or two
Enable or disable parity
Set the printer to ignore data errors or print a “? upon encountering an error
The settings used will depend on the software the operator is using and the capabilities
of the host computer.
Press the Paper Feed button for the communications settings you want.
Defaults are marked with asterisks (*).