SSA Scripting 62
options in the file as necessary for the target system. This method is useful for applying a standard
configuration to several servers that have similar storage resources.
Write an original script.
Each line of text in an SSA script file is in the format option=value and can be written in uppercase or
lowercase letters. For information about possible option values and the minimum configuration
information that a valid script must have, see the sample custom input script.
You can add blank lines and comments to any script to make it easier to read and understand. To create a
comment, enter a semicolon, and then enter the comment text. SSA ignores all text on the same line after a
semicolon.
Script file requirements
The script file used by SSA Scripting is a text file that contains options and parameters required to configure
array controllers. In order to be successfully implemented, scripts must follow the guidelines below:
Ordering of the options and parameters is important. Options need to be read in the sequence
Control>Controller>Array>Logical Drive.
Lines of the script file are written in the form option=value or left blank.
Semicolons are used for comments within script files. If the first character in the line is a semicolon,
SSA Scripting ignores everything up to the next line.
Sample custom input script
The sample script in this section gives all possible values for each option.
If an option is shown in bold type, you must enter a value for that option when writing your own script.
Default options are not universal across controllers and firmware.
You can use this script as a template for your own script.
Action = Configure|Reconfigure
Method = Custom
Controller = All|Slot [N][:N] | WWN [N] | First | SerialNumber [N] | IOCabinet [N],IOBay [N],IOChassis
[N],Slot [N],Cabinet [N],Cell [N]
ClearConfigurationWithDataLoss = Yes|No |Forced
ReadCache = 0|10|20|25|30|40|50|60|70|75|80|90|100
WriteCache = 0|10|20|25|30|40|50|60|70|75|80|90|100
RapidParityInitalization = Enable|Disable
RebuildPriority = Low|Medium|Mediumhigh|High
ExpandPriority = Low|Medium|High
SurfaceScanDelay = N
SurfaceScanDelayExtended = N
SurfaceScanMode = Idle|High|Disabled
DriveWriteCache = Enable|Disable
NoBatteryWriteCache = Enable|Disable
BootVolumePrimary = Logical Drive Number|None
BootVolumeSecondary = Logical Drive Number|None
PowerMode = MinPower|Balanced|MaxPerformance
Latency = Disable|Low|High
; Array Options
; There can be multiple array specifications in the file
Array = A|B|C|D|E|F|G|...Z|AA|AB|AC... | Next
Drive = Port:ID... | Box:Bay... | Port:Box:Bay,... | N | *
OnlineSpareMode = Dedicated | AutoReplace
OnlineSpare = Port:ID,... | Box:Bay,... | Port:Box:Bay | None | N
SplitMirror = SplitWithBackup|Rollback|Remirror|ActivateBackup

Table of Contents

Other manuals for NEC Express 5800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Express 5800 Series and is the answer not in the manual?

NEC Express 5800 Series Specifications

General IconGeneral
BrandNEC
ModelExpress 5800 Series
CategoryServer
LanguageEnglish

Related product manuals