UNIVERGE SV8100 Issue 5.0
Transfer 1 - 1007
20-11-18 Class of Service Options (Hold/
Transfer Service) – No Recall
Allow (0) or deny (1) unanswered
Transferred calls to the COS from
recalling the originating extension.
. For example, with this option
set to 1 for COS 1, calls
transferred by any COS to
any extension with a COS of
1, do not recall.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-11-20 Class of Service Options (Hold/
Transfer Service) – No Callback
Turns Off or On an extension to
receive callbacks.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
Allows a busy extension the ability
to manually (0) or automatically (1)
receive off-hook signals.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-13-10 Class of Service Options
(Supplementary Service) –
Barge-In Monitor
Enables the extension Barge-In
Mode to be speech mode (0) or
Monitor mode (1) (i.e., Barge-In
initiator). This is required to
transfer a call into a conference.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-13-15 Class of Service Options
(Supplementary Service) –
Barge-In, Initiate
Turns off (0) or on (1) an extension
user ability to barge-in on other's
calls.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-13-16 Class of Service Options
(Supplementary Service) –
Barge-In, Receive
In an extension COS, turn On (1)
or Off (0) the ability to receive a
Barge-In on a call.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-13-17 Class of Service Options
(Supplementary Service) –
Barge-In Tone/Display (Intrusion
Tone)
Turn On (1) or Off (0) the Barge-In
Tone. If disabled, this also turns off
the Barge-In display at the called
extension. As this option is for
extensions and trunks do not have
an option for a Barge-In Tone, the
tone is sent to the trunks based on
the Class of Service of the
transferring extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-13-32 Class of Service Options
(Supplementary Service) – Deny
Multiple Barge-Ins
In an extension Class of Service,
allow (1) or deny (0) the extension
ability to have multiple users
Barge-In to their conversation.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-14-11 Class of Service Options For
DISA/E&M – DISA/Tie Trunk
Barge-In
In an extension Class of Service,
enable (1) or disable (0) a DISA or
tie trunk user from using the
Barge-In feature.
0 = Off
1 = On
(default = 0 for
COS 1~15)