Issue 5.0 UNIVERGE SV8100
1 - 1062 UNIVERGE Multimedia Conference Bridge
10-55-04 Package Network Setup – Sub
Net Mask
Define the subnet mask for the
CD-ETIA.
128.0.0.0
192.0.0.0
224.0.0.0
240.0.0.0
248.0.0.0
252.0.0.0
254.0.0.0
255.0.0.0
255.128.0.0
255.192.0.0
255.224.0.0
255.240.0.0
255.248.0.0
255.252.0.0
255.254.0.0
255.255.0.0
255.255.128.0
255.255.192.0
255.255.224.0
255.255.240.0
255.255.248.0
255.255.252.0
255.255.254.0
255.255.255.0
255.255.255.128
255.255.255.192
255.255.255.224
255.255.255.240
255.255.255.248
255.255.255.252
255.255.255.254
255.255.255.255
(default = 255.255.0.0)
10-55-05 Package Network Setup –
Default Gateway
Define the default gateway for the
CD-ETIA.
0.0.0.0 ~
126.255.255.254
128.0.0.1 ~
191.255255.254
192.0.0.1 ~
223.255.255.254
(default = 0.0.0.0)
11-02-01 Extension Numbering Assign extension numbers to
extension ports. The telephone
programming identity follows the
port number – not the extension
number.
Up to eight digits
1 101
2 102
3 103
~ ~
99 199
100 3101
~ ~
512 3513
Program
Number
Program Name Description/Comments Assigned Data