EasyManua.ls Logo

NEC Univerge SV8100 - Page 1073

NEC Univerge SV8100
1174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 5.0
UNIVERGE Multimedia Conference Bridge 1 - 1063
11-07-01 Department Group Pilot
Numbers – Dial
Assign a Department Group pilot
number for the CNF(8)-U ETU
(eight digits max). The extensions
are assigned to the group in
Program 16-02-01.
Up to eight digits
(default not assigned)
15-03-01 Single Line Telephone Basic
Data Setup – SLT Signaling Type
For each SLT extension, this
option must be set to 0.
0 = DP
1 = DTMF
(default = 1)
15-03-03 Single Line Telephone Basic
Data Setup – Terminal Type
Enter 1 for this option to allow a
single line port to receive DTMF
tones after the initial call setup.
Enter 0 to have the port ignore
DTMF tones after the initial call
setup. For Voice Mail, always
enter 1 (e.g., receive DTMF
tones).
0 = Normal
1 = Special
(default = 0)
16-01-01 Department Group Basic Data
Setup – Department Name
Assign a name to the Extension
(Department) Groups.
Maximum 12
characters
(default not assigned)
16-01-02 Department Group Basic Data
Setup – Department Calling
Cycle
Set the routing cycle for calls into
a department (i.e., when a user
dials the department pilot
number). The system can ring the
highest priority extension available
(Priority Routing, 0) or cycle in
circular order to a new idle
extension for each new call
(Circular Routing, 1).
0 = Normal Routing
(Priority)
1 = Easy – UCD
Routing (Circular)
(default = 0)
16-01-03 Department Group Basic Data
Setup – Department Routing
When Busy (Auto Step Call)
Set how the system routes an
Intercom call to a busy
Department Group member. The
caller can hear busy tone (0) or
overflow to the first available
Department Group member (1).
This option is for Intercom calls to
an extension, not a pilot number.
0 = Normal (Intercom
caller to busy
department member
hears busy)
1 = Circular (Intercom
callers to busy
department member
routes to idle member)
(default = 0)
16-01-04 Department Group Basic Data
Setup – Hunting Mode
Set if an unanswered call should
hunt once stopping at the last
member tried (0) or continually
hunt through the idle members (1).
0 = Last extension is
called and hunting is
stopped
1 = Circular
(default = 0)
Program
Number
Program Name Description/Comments Assigned Data

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals