Issue 5.0 UNIVERGE SV8100
1 - 394 Direct Inward Dialing (DID)
20-09-01 Class of Service Options
(Incoming Call Service) –
Second Call for DID/DISA/DIL/
E&M Override
Turns Off (0) or On (1) the
extension ability to receive a
second call from a DID, DISA, DIL,
or tie line caller.
. With this option set to 1, the
destination extension must
be busy for a second DNIS
caller to ring through. If the
destination extension does
not have a trunk or CAP key
available for the second call
and a previous call is ringing
the extension but has not yet
been answered, the second
caller hears busy regardless
of this program setting.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-13-23 Class of Service Options
(Supplementary Service) –
Display the Reason for Transfer
Select whether an extension
should display the reason a call is
being transferred to their
extension (Call Forward Busy, Call
Forward No Answer, DND).
0 = Off
1 = On
(default = 0 for
COS 1~15)
21-01-02 System Options for Outgoing
Calls – Intercom Interdigit Time
Set the time-out interval for DID
callers that do not dial. After this
time, the DID call routes according
to Vacant Number Intercept
programming.
0~64800 (seconds)
(default = 10 seconds)
22-01-06 System Options for Incoming
Calls – DID Ring-No-Answer
Time
Set the DID Ring No Answer
(RNA) Intercept time (0~64800
seconds). In systems with RNA
Intercept, the DID call rings the
destination extension for this time,
and then rings Intercept Ring
Group. (default: 20).
0~64800 (seconds)
(default = 20 seconds)
22-02-01 Incoming Call Trunk Setup For each Night Service Mode,
enter service type 3 when the
trunk should be a DID trunk.
Trunks 1~200
0 = Normal
1 = VRS (second
dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode
Switching
(default = 0)
Program
Number
Program Name Description/Comments Assigned Data