UNIVERGE SV8100 Issue 5.0
Direct Inward Dialing (DID) 1 - 395
22-04-01 Incoming Extension Ring Group
Assignment
Assign extensions to Ring Groups.
Calls ring the extensions
according to programming in
Program 22-06.
Maximum eight digits
Default:
Extensions 101~108
(first eight ports) ring
for incoming Ring
Group 1 calls. No
other extensions ring
for incoming Ring
Group 1 calls.
22-09-01 DID Basic Data Setup – Expected
Number of Digits
For each DID Translation Table
(1~20), enter the number of digits
the table expects to receive from
the CO (eight maximum). For
example, for a table used with
3-digit DID service, enter 3.
1~8
(default = 4)
22-09-02 DID Basic Data Setup – Received
Vacant Number Operation
Use this option to enable or
disable Vacant Number Intercept.
0 = Disconnect
1 = Transfer
(default = 0)
22-10-01 DID Translation Table Setup Assign the start and end range of
DID Translation Table entries
(1~2000) to each DID Translation
Table (1~20).
0~2000
(0 = No Setting)
default:
1st:
1 Start – 1, End – 100
2 Start – 101, End –
200
3 Start – 201, End –
300
4 Start – 301, End –
400
5~20 Start – 0, End – 0
2nd:
1~20 Start – 0, End – 0
22-11-01 DID Translation Number
Conversion – Received Number
For each DID Translation Table
entry (1~2000), specify the digits
received by the system.
Maximum eight digits
(default not assigned)
22-11-02 DID Translation Number
Conversion – Target Number
For each DID Translation Table
entry (1~2000), specify the
extension the system dials after
translation.
Maximum 24 digits
(default not assigned)
22-11-03 DID Translation Number
Conversion – DID Name
For each DID Translation Table
entry (1~2000), specify the name
that should show on the dialed
extension display when it rings.
Maximum 12 digits
(default not assigned)