7 MAINTENANCE
PAGE
7.1
Date Name Signed Revision: 2
issued 07.12.94 Mangel Substitute for issue
approved 08.12.94 Eitler of 18.03.94
released 09.12.94 Hantschk
text no. 30100
copy to:
7.2 Lubrication
The NEMO
®
pump does not require
frequent lubrication.
■ Maintenance of the drive should be carried out according
to the drive manufacturers instructions.
■ Maintenance
– where no manufacturers instructions are available and
– when normal conditions of use exist:
– Strip down the drive unit
– Remove the bearings
– Clean all parts
– Renew the lubricant
every 5000 operating hours or at least every two years.
Special lubricants are often specified for mechanically
controlled variable speed drives.
It is therefore important to follow the drive manufacturers
maintenance instructions.