TABLE 3 - LFR GENERAL INSTRUCTIONS
BURNER AIR DIRECT DRIVE TAP
MODEL
RIELLO
BURNER
B.T.U.H.
OUTPUT
B.T.U.H.
INPUT
(USGPH)
AFUE
%
NOZZLE
PUMP
p.s.i..
INSERTION
inches
BAND SHUTTER
CHIMNEY
FLUE
PRESSURE
(in. w.c.)
STACK
o
F
FILTER
10" BLOWER 9" BLOWER
EXTERNAL
STATIC
PRESSURE
(in. w.c.)
MED-LO MED-HI 0.20
LFR-88 40 F3 88,000 101,762(0.73) 81.7 Delavan 0.60 60A 150 2" 1.5 3.4 -0.02 380 20" x 25"
MED-HI 0.50
LO MED-LO 0.20
MED-LO HI 0.50
LFR-75 40 F3 75,000 85,034(0.61) 81.2 Delavan 0.50 80B 150 2" 0.5 2.7
-0.02
350 20" x 25"
LO MED-HI 0.50
BURNER AIR DIRECT DRIVE TAP
MODEL
BECKETT
BURNER
B.T.U.H.
OUTPUT
B.T.U.H.
INPUT
(USGPH)
AFUE
%
NOZZLE
PUMP
p.s.i..
INSERTION
Inches
SHUTTER BAND
CHIMNEY
FLUE
PRESSURE
(in. w.c.)
STACK
o
F
FILTER
10" BLOWER 9" BLOWER
EXTERNAL
STATIC
PRESSURE
(in. w.c.)
MED-LO MED-HI 0.20
LFR-89V AFG70MM 89,000 101,762(0.73) 82.2 Hago 0.55 45B 180 2-3/8" 6 0 -0.02 400 20" x 25"
MED-HI 0.50
MED-LO MED-HI 0.20
LFR-80V AFG70MM 81,000 93,398(0.61) 82.0 Hago 0.50 45B 180 2-3/8" 7.5* 0
-0.02
360 20" x 25"
MED-LO HI 0.50
* USE LOW FIRING RATE BAFFLE
BURNER AIR DIRECT DRIVE TAP
MODEL
RIELLO
BURNER
B.T.U.H.
OUTPUT
B.T.U.H.
INPUT
(USGPH)
AFUE
%
NOZZLE
PUMP
p.s.i..
INSERTION
inches
TURB SHUTTER
CHIMNEY
FLUE
PRESSURE
(in. w.c.)
STACK
o
F
FILTER
10" BLOWER 9" BLOWER
EXTERNAL
STATIC
PRESSURE
(in. w.c.)
MED-LO MED-HI 0.20
LFR-86V BF3 86,000 100,386(0.72) 82.3 Delavan 0.60 60A 145 2" 1.5 4.4 -0.02 380 20" x 25"
MED-HI 0.50
LO MED-LO 0.20
LFR-73V BF3 73,000 83,640(0.60) 81.9 Delavan 0.50 80B 145 2" 1 3.8
-0.02
350 20" x 25"
MED-LO HI 0.50
BURNER AIR DIRECT DRIVE TAP
MODEL
CARLIN
BURNER
B.T.U.H.
OUTPUT
B.T.U.H.
INPUT
(USGPH)
AFUE
%
NOZZLE
PUMP
p.s.i..
INSERTION
inches
POS BAR BAND
CHIMNEY
FLUE
PRESSURE
(in. w.c.)
STACK
o
F
FILTER
10" BLOWER 9" BLOWER
EXTERNAL
STATIC
PRESSURE
(in. w.c.)
MED-LO MED-HI 0.20
LFR-87 EZ PRO 87,000 101,762(0.73) 81.7 Delavan 0.60 60A 150 1-1/2" 0.60/0.65 0.75 -0.02 390 20" x 25"
MED-HI 0.50
LFR-72 EZ PRO 73,000 85,034(0.61) 80.7 Delavan 0.50 60A 150 1-1/2" 0.5 0.60
-0.02
360 20" x 25" LO MED-LO 0.20
Models marked -V can be used with the Newmac SVS sealed vent system.
Use burner air settings as a guide only. Set burner air to give a trace of smoke. Re-adjust burner air to reduce CO
2
by 1 to 1.5 percent.
Take measurements with the burner cover & air ducts installed (if any). The minimum recommended temperature rise is 65
o
F.
The maximum allowable temperature rise is 85
o
F. Select speed to suit specific installation requirements.
Air temperature can be lowered by increasing the blower speed, lowering the firing rate, or increasing supply & return outlets.
TABLE 4 - LFR BLOWER PERFORMANCE
DIRECT DRIVE
BLOWER
BLOWER
MOTOR
SPEED
TAP
RPM
STATIC
PRESSURE
(IN. W.C.)
CFM
A/C
TONS
HIGH 1,080 1,200 3.00
MED-HI 1.030 1,000 2.50
MED-LO 960 875 2.00
DELHI GT 10DD
1/3 HP
4 SPD
LO 910
0.50
750 1.75
HIGH 1,050 1,350
MED-HI 850 1,200
MED-LO 740 1,000
DELHI GT 10DD
1/3 HP
4 SPD
LO 670
0.20
800