Pipe connections
13
FIGHTER 1240
The installation can be supplemented with the exhaust
air module FLM to provide ventilation recovery.
Pipes and other cold surfaces must be insulated with
diffusion-proof material to prevent condensation.
The collector circuit should be fitted with a pressure
expansion
vessel. If there is a level vessel, this
should be replaced.
The equipment can be supplemented with a fan coil
unit to make the connection of ambient cooling possi-
ble.
To avoid condensation, all pipes and other cold sur-
faces must be isolated with diffusion-proof material.
Where the cooling demand is high, fan convectors
with drip trays and drain connection are needed.
The collector circuit should be fitted with a pressure
expansion
vessel. If there is a level vessel, this
should be replaced.
Free cooling
Ventilation recovery
Brine in
Fan convectors
Brine out
Brine in
Extract air
Ø 160
Exhaust air
Ø 160
Brine out