Control
FIGHTER 1240
42
Menu 8.3.0 Current limiter
Settings and readings regarding the load monitor are
set in the sub-menus to this menu. NOTE! No function
in a 1-phase installation.
Current limiter
8.3.0
Menu 8.3.5 Max. add heat
The setting selected on the EBV card (2) knob (101) is
shown here.
2
Max. add heat
8.3.5
Menu 8.3.7 Return
Pressing the enter button returns you to menu 8.3.0.
Return
8.3.7
Menu 8.3.4 Fuse size
The setting selected on the EBV card (2) knob (100) is
shown here.
16 A
Fuse size
8.3.4
Menu 8.3.1 Current phase 1
Shows the measured current from phase 1. If the val-
ue falls below 2.0 A low is shown.
3.5 A
Current phase 1
8.3.1
Menu 8.3.2 Current phase 2
Shows the measured current from phase 2. If the val-
ue falls below 2.0 A low is shown.
3.3 A
Current phase 2
8.3.2
Menu 8.3.3 Current phase 3
Shows the measured current from phase 3. If the val-
ue falls below 2.0 A low is shown.
3.3 A
Current phase 3
8.3.3
Menu 8.3.6 EBV value
The transfer value must be defined depending on the
current transformers used for the EBV card. The value
is adjustable between 100 and 900 in increments of
10. The setting 300 applies for the supplied current
transformers.
300
EBV value
8.3.6
U
U
U
U
U
U
U
Other settings
Menu 8.4.1 Pooltemp./Setting
The temperature when pool heating is stopped is stat-
ed here.
The value is adjustable between 5 and 55 °C.
19.0 (20)°C
Pooltemp./Setting
8.4.1
Menu 8.4.2 Diff. Pool/min-temp
The difference from the value in menu 8.4.1 when
pool heating starts is stated here.
The value is adjustable between 0.5 and 9.5 °C.
1.5°C
Diff. Pool/min-temp
8.4.2
U
U
Menu 8.4.0 Pool adjustments
Pool settings are made in the submenus to this menu.
Pool adjustments
8.4.0