Service menus
45
FIGHTER 1240
Menu 9.2.9.1 Floor drying
The floor drying program is chosen from this sub-
menu. The options are Prog 1 On, Prog 2 On or Off
The heat pump must be in Winter mode, selected with
the operating mode button. Electric boiler mode, Menu
9.2.4 can be used together with floor drying, for exam-
ple, when the heat source is not installed.
In Prog 1 On, menus 9.2.9.2 — 9.2.9.5 are shown.
After time period 1 switching to time period 2 then
Return to normal settings.
In Prog 2 On, a fixed program over 11 days is fol-
lowed. The flow temperature is increased from 20°C
to 45°C for 4 days, it then remains constant for 3 days.
The temperature then steps down to 25°C for 4 days,
and then returns to the normal settings.
Off
Floor drying
9.2.9.1
Menu 9.2.9.2 Numb. of days per. 1
Selection of the number of days in period 1.
The value is adjustable between 1 to 5.
3
Numb. of days per. 1
9.2.9.2
Menu 9.2.9.3 Temp. period 1
Selection of the flow temperature in period 1.
The value is adjustable between 15 and 50 °C.
25°C
Temp. period 1
9.2.9.3
S
S
S
Menu 9.2.9.4 Numb. of days per. 2
Selection of the number of days in period 2.
The value is adjustable between 1 to 5.
1
Numb. of days per. 2
9.2.9.4
Menu 9.2.9.5 Temp. period 2
Selection of the flow temperature in period 2.
The value is adjustable between 15 and 50 °C.
40°C
Temp. period 2
9.2.9.5
S
S
Menu 9.2.10 Pool control
Settings whether pool control should be On or Off.
Basic setting is Off.
Off
Pool control
9.2.10
S
Operating settings
Menu 9.2.9.6 Return
Pressing the enter button returns you to menu 9.2.9.0
Return
9.2.9.6
S
Menu 9.2.11 Brine pressostat
You set here whether an external an brine presso-
stat/load monitor is connected to the load monitor
card.
Off
Brine pressostat
9.2.11
S
Menu 9.2.12 Oper. mode brinepump
The operating mode for the brine pump is set here.
Selectable options are:
Intermittent: The brine pump starts 20 seconds
before and stops 20 seconds after the compressor.
Continuous: Continuous operation.
10 days. cont: Continuous operation for 10 days.
Then the pump shifts to intermittent mode.
Intermittent
Oper. mode brinepump
9.2.12
S